EXPLORATION OF STABILITY-INDICATING ASSAY UHPLC METHOD FOR SIMULTANEOUS ANALYSIS OF SITAGLIPTIN AND METFORMIN IN PURE MATERIAL AND PHARMACEUTICAL DOSAGE FORMS

Main Article Content

Rahul P Umbarkar
Abhilasha Mittal
Manoj S Charde

Abstract

The scientific novelty of designed work was to develop a specific and precise stability-indicating ultra high performance liquid chromatography (UHPLC) assay method for simultaneous quantification of Sitagliptin and Metforminin extendedrelease fixed dose combinations (FDCs). The reversed-phase UHPLC resolution was analyzed with the assistance of
UPLC BEH C18 (150 mm 2.1 mm) with 1.7 µm particle size column at ambient temperature using a solvent system in
a proportion of (90:10 % v/v) acetonitrile: potassium dihydrogen orthophosphate buffer; pH 3.0±0.2 was adjusted with
0.1 % ortho phosphoric acid (OPA), with flow rate of 0.4 mL/min of the solvent system. The analytes were supervised
at 267 nm by employing photodiode array recognition. The retention times of Sitagliptin and Metformin were found to
be1.903±0.01 and 1.301±0.022, respectively. The Sitagliptin and Metformin have confirmed the linearity ranges of 5-
30μg/mL, and 100-600 μg/mL respectively, with 0.9996 and 0.9996 determination coefficients. The UHPLC method
was effectually validated concerning the accuracy, precision, sensitivity, robustness, ruggedness, selectivity, and
specificity. Moreover, the anticipated UHPLC method's capability to analyze the Sitagliptin and Metformin with no
obstruction from degradation products.

Downloads

Download data is not yet available.

Article Details

How to Cite
Umbarkar, R., Mittal, A., & Charde, M. (2022). EXPLORATION OF STABILITY-INDICATING ASSAY UHPLC METHOD FOR SIMULTANEOUS ANALYSIS OF SITAGLIPTIN AND METFORMIN IN PURE MATERIAL AND PHARMACEUTICAL DOSAGE FORMS. Journal of Advanced Scientific Research, 13(03), 118-125. https://doi.org/10.55218/JASR.202213319